Design
Per EN 837-1, including transport case and acceptance test certificate (individual listing of the calibration points)
Nominal size in mm
250
Accuracy class
0.1: for scale ranges <0 ... 400 bar
0.25: for scale ranges ≥0 ... 400 bar
Scale ranges
0 ... 1.0 bar to 0 ... 1,600 bar
or all other equivalent vacuum or combined pressure and vacuum ranges
Adjustment medium
≤25 bar: Gas
>25 bar: Water
Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Permissible temperature
Ambient: -20°C … +60°C
Medium: +100°C maximum
Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20°C):
Max. ±0.1%/10 K of full scale value
Ingress protection
IP54 per IEC/EN 60529